Loading...
Header Logo
Keywords
Last Name
Institution

Suncica Canic

TitleProfessor
InstitutionUniversity of Houston
DepartmentMathematics
Address4800 Calhoun Rd
Houston TX 77004
Phone713-743-3466
vCardDownload vCard

    Collapse Bibliographic 
    Collapse selected publications
    Publications listed below are automatically derived from MEDLINE/PubMed and other sources, which might result in incorrect or missing publications. Faculty can login to make corrections and additions.
    List All   |   Timeline
    1. Wang Y, Quaini A, Canic S, Vukicevic M, Little SH. 3D Experimental and Computational Analysis of Eccentric Mitral Regurgitant Jets in a Mock Imaging Heart Chamber. Cardiovasc Eng Technol. 2017 Jul 10. PMID: 28695443.
      View in: PubMed
    2. Zunino P, Tambaca J, Cutrì E, Canic S, Formaggia L, Migliavacca F. Integrated Stent Models Based on Dimension Reduction: Review and Future Perspectives. Ann Biomed Eng. 2016 Feb; 44(2):604-17. PMID: 26452562.
      View in: PubMed
    3. Kheradvar A, Groves EM, Falahatpisheh A, Mofrad MK, Hamed Alavi S, Tranquillo R, Dasi LP, Simmons CA, Jane Grande-Allen K, Goergen CJ, Baaijens F, Little SH, Canic S, Griffith B. Emerging Trends in Heart Valve Engineering: Part IV. Computational Modeling and Experimental Studies. Ann Biomed Eng. 2015 Oct; 43(10):2314-33. PMID: 26224522.
      View in: PubMed
    4. Kheradvar A, Groves EM, Dasi LP, Alavi SH, Tranquillo R, Grande-Allen KJ, Simmons CA, Griffith B, Falahatpisheh A, Goergen CJ, Mofrad MR, Baaijens F, Little SH, Canic S. Emerging trends in heart valve engineering: Part I. Solutions for future. Ann Biomed Eng. 2015 Apr; 43(4):833-43. PMID: 25488074.
      View in: PubMed
    5. Kheradvar A, Groves EM, Goergen CJ, Alavi SH, Tranquillo R, Simmons CA, Dasi LP, Grande-Allen KJ, Mofrad MR, Falahatpisheh A, Griffith B, Baaijens F, Little SH, Canic S. Emerging trends in heart valve engineering: Part II. Novel and standard technologies for aortic valve replacement. Ann Biomed Eng. 2015 Apr; 43(4):844-57. PMID: 25449148.
      View in: PubMed
    6. Kheradvar A, Groves EM, Simmons CA, Griffith B, Alavi SH, Tranquillo R, Dasi LP, Falahatpisheh A, Grande-Allen KJ, Goergen CJ, Mofrad MR, Baaijens F, Canic S, Little SH. Emerging trends in heart valve engineering: Part III. Novel technologies for mitral valve repair and replacement. Ann Biomed Eng. 2015 Apr; 43(4):858-70. PMID: 25287646.
      View in: PubMed
    7. Passerini T, Quaini A, Villa U, Veneziani A, Canic S. Validation of an open source framework for the simulation of blood flow in rigid and deformable vessels. Int J Numer Method Biomed Eng. 2013 Nov; 29(11):1192-213. PMID: 23798339; PMCID: PMC3844109.
    8. Bukac M, Canic S. Longitudinal displacement in viscoelastic arteries: a novel fluid-structure interaction computational model, and experimental validation. Math Biosci Eng. 2013 Apr; 10(2):295-318. PMID: 23458302.
      View in: PubMed
    9. Quaini A, Canic S, Glowinski R, Igo S, Hartley CJ, Zoghbi W, Little S. Validation of a 3D computational fluid-structure interaction model simulating flow through an elastic aperture. J Biomech. 2012 Jan 10; 45(2):310-8. PMID: 22138194; PMCID: PMC3274367.
    10. Quaini A, Canic S, Paniagua D. Numerical characterization of hemodynamics conditions near aortic valve after implantation of Left Ventricular Assist Device. Math Biosci Eng. 2011 Jul; 8(3):785-806. PMID: 21675811.
      View in: PubMed
    11. Quaini A, Canic S, Guidoboni G, Glowinski R, Igo SR, Hartley CJ, Zoghbi WA, Little SH. A Three-Dimensional Computational Fluid Dynamics Model of Regurgitant Mitral Valve Flow: Validation Against in vitro Standards and 3D Color Doppler Methods. Cardiovasc Eng Technol. 2011 Jun; 2(2):77-89. PMID: 22582092.
      View in: PubMed
    12. Tambaca J, Canic S, Kosor M, Fish RD, Paniagua D. Mechanical behavior of fully expanded commercially available endovascular coronary stents. Tex Heart Inst J. 2011; 38(5):491-501. PMID: 22163122; PMCID: PMC3231552.
    13. Tambaca J, Canic S, Paniagua D. A comparison between fractured Xience-like and Palmaz-like stents using a novel computational model. Conf Proc IEEE Eng Med Biol Soc. 2009; 2009:1106-8. PMID: 19964749.
      View in: PubMed
    14. Canic S, Rosenstrauch D. Use of auricular chondrocytes for lining artificial surfaces: a mathematical model. IEEE Trans Nanobioscience. 2008 Sep; 7(3):240-5. PMID: 18779105.
      View in: PubMed
    15. Canic S, Hartley CJ, Rosenstrauch D, Tambaca J, Guidoboni G, Mikelic A. Blood flow in compliant arteries: an effective viscoelastic reduced model, numerics, and experimental validation. Ann Biomed Eng. 2006 Apr; 34(4):575-92. PMID: 16550449.
      View in: PubMed
    16. Canic S, Ravi-Chandar K, Krajcer Z, Mirkovic D, Lapin S. Mathematical Model analysis of Wallstent and Aneurx: dynamic responses of bare-metal endoprosthesis compared with those of stent-graft. Tex Heart Inst J. 2005; 32(4):502-6. PMID: 16429893; PMCID: PMC1351820.
    17. Canic S, Tambaca J, Mikelic A, Hartley CJ, Mirkovic D, Chavez J, Rosenstrauch D. Blood flow through axially symmetric sections of compliant vessels: new effective closed models. Conf Proc IEEE Eng Med Biol Soc. 2004; 5:3696-9. PMID: 17271096.
      View in: PubMed
    Canic's Networks
    Click the "See All" links for more information and interactive visualizations!
    Concepts Expand Description
    _
    Co-Authors Expand Description
    _
    Similar People Expand Description
    _
    Same Department Expand Description
    Physical Neighbors Expand Description
    _